AC power transmission AC power transmission is the transmission of electric power by alternating current. Usually transmission lines use three phase AC current. In electric railways, single phase AC current is sometimes used in a railway electrification system. In urban areas, trains may be powered by DC at 600 volts or so. Today, transmission-level voltages are usually considered to be 110 kV and above. Lower voltages such as 66 kV and 33 kV are usually considered sub-transmission voltages but are occasionally used on long lines with light loads. Voltages less than 33 kV are usually used for distribution. Voltages above 230 kV are considered extra high voltage and require different designs compared to equipment used at lower voltages. Overhead transmission lines are not insulated, so design of these lines requires minimum clearances to be observed to maintain safety. History In an AIEE Address, May 16, 1888, Nikola Tesla delivered a lecture entitled A New System of Alternating Current Motors and Transformers, describing the equipment which allowed efficient generation and use of alternating currents. Tesla's disclosures, in the form of patents, lectures and technical articles, are useful for understanding the history of the modern system of power transmission. Ownership of the rights to the Tesla patents was a key commercial advantage to the Westinghouse company in offering a complete alternating current power system for both lighting and power. The first transmission of three-phase alternating current using high voltage took place in the year 1891 on the occasion of the international electricity exhibition in Frankfurt. In that year, a 25 kV transmission line, approximately 175 kilometres long, was built between Lauffen at the Neckar and Frankfurt. The rapid industrialization in the 20th century made electrical transmission lines and grids a critical part of the economic infrastructure in most industrialized nations. Initially transmission lines were supported by porcelain pin-and-sleeve insulators similar to those used for telegraph and telephone lines. However, these reached a practical limit of 40 kV. In 1907 the invention of the disc insulator by Harold W. Buck of the Niagara Falls Power Corporation and Edward M. Hewlett of General Electric allowed practical insulators of any length to be constructed, which allowed the use of higher voltages. The first large scale hydroelectric generators in the USA (embodying the patents of Nikola Tesla) were installed at Niagara Falls and provided electricity to Buffalo, New York via power transmission lines. A statue of Tesla stands at Niagara Falls today in tribute to his contributions. Voltages used for electric power transmission increased throughout the 20th century. The first three-phase alternating current power transmission at 110 kV took place in 1912 between Lauchhammer and Riesa, Germany. On April 17, 1929 the first 220 kV line in Germany was completed, running from Brauweiler near Cologne, over Kelsterbach near Frankfurt, Rheinau near Mannheim, Ludwigsburg-Hoheneck near Austria. The masts of this line were designed for eventual upgrade to 380 kV. However the first transmission at 380 kV in Germany was on October 5, 1957 between the substations in Rommerskirchen and Ludwigsburg-Hoheneck. In 1967 the first extra-high-voltage transmission at 735 kV took place on a Hydro-Québec transmission line. In 1982 the first transmission at 1200 kV took place in the Soviet Union. Bulk power transmission
Grid input At the generating plants the energy is produced at a relatively low voltage of up to 30 kV (Grigsby, 2001, p. 4-4), then stepped up by the power station transformer to a higher voltage for transmission over long distances to grid exit points (substations). Losses It is necessary to transmit the electricity at high voltage to reduce the fraction of energy lost. For a given amount of power transmitted, a higher voltage reduces the current and thus the resistive losses in the conductor. Long distance transmission is typically done with overhead lines at voltages of 110 to 1200 kV. However, at extremely high voltages, more than 2000 kV between conductor and ground, corona discharge losses are so large that they can offset the lower heating loss in the line conductors. Transmission and distribution losses in the USA were estimated at 7.2% in 1995 *, and in the UK at 7.4% in 1998. * In an alternating current transmission line, the inductance and capacitance of the line conductors can be significant. The currents that flow in these components of transmission line impedance constitute reactive power, which transmits no energy to the load. Reactive current flow causes extra losses in the transmission circuit. The fraction of total energy flow (power) which is resistive (as opposed to reactive) power is the power factor. Utilities add capacitor banks and other components throughout the system—such as phase-shifting transformers, static VAr compensators, and flexible AC transmission systems (FACTS)—to control reactive power flow for reduction of losses and stabilization of system voltage. HVDC High voltage DC (HVDC) is used to transmit large amounts of power over long distances or for interconnections between asynchronous grids. When electrical energy is required to be transmitted over very long distances, it can be more economical to transmit using direct current instead of alternating current. For a long transmission line, the value of the smaller losses, and reduced construction cost of a DC line, can offset the additional cost of converter stations at each end of the line. Also, at high AC voltages significant amounts of energy are lost due to corona discharge, the capacitance between phases or, in the case of buried cables, between phases and the soil or water in which the cable is buried. Since the power flow through an HVDC link is directly controllable, HVDC links are sometimes used within a grid to stabilize the grid against control problems with the AC energy flow. One prominent example of such a transmission line is the Pacific Intertie located in the Western United States. Power Loss Electrical power is invariably partially lost during transmission. This applies to short distances such as between components on a printed circuit board as well as to cross country high voltage lines. Loss power is proportional to the resistance of the wire and the square of the current. Because of this relationship, it is favourable to transmit energy with voltages as high as possible. This reduces the current and thus the power lost during transmission. Grid exit At the substations, transformers are again used to step the voltage down to a lower voltage for distribution to commercial and residential users. This distribution is accomplished with a combination of sub-transmission (33 kV to 115 kV, varying by country and customer requirements) and distribution (3.3 to 25 kV). Finally, at the point of use, the energy is transformed to low voltage (100 to 600 V, varying by country and customer requirements). Communications
Electricity market reform Transmission is a natural monopoly and there are moves in many countries to separately regulate transmission (see New Zealand Electricity Market). In the USA the Federal Energy Regulatory Commission had issued a notice of proposed rulemaking setting out a proposed Standard Market Design (SMD) that would see the establishment of Regional Transmission Organizations (RTOs). The first RTO in North America is the Midwest Independent Transmission System Operator (MISO) *. MISO's authority covers parts of the transmission grid in the United States midwest and one province of Canada (through a coordination agreement with Manitoba Hydro). MISO also operates the wholesale power market in the United States portion of this area. In July 2005, the new FERC chairman, Joseph Kelliher announced the end of SMD efforts because "the rulemaking had been overtaken by the voluntary formation of RTOs and ISOs" according to FERC. Spain was the first country to establish a Regional Transmission Organization. In that country transmission operations and market operations are controlled by separate companies. The transmission system operator is Red Eléctrica de España (REE) * and the wholesale electricity market operator is Operador del Mercado Ibérico de Energía - Polo Español, S.A. (OMEL) *. Spain's transmission system is interconnected with those of France, Portugal, and Morocco. Merchant Transmission Merchant transmission is a reform where a third party constructs and operates electric transmission lines through the frachise area of an unrelated utility. Advocates of merchant transmission claim that this will create competition to construct the most efficient and lowest cost additions to the transmission grid. Merchant transmission projects typically involve DC lines because it is easier to limit flows to paying customers. The only operating merchant transmission project in the United States is the Cross Sound Cable from Long Island, New York to New Haven, CT, although additional projects have been proposed. There are five merchant transmission interconnectors between five states in Australia: the DirectLink, MurrayLink and Southern Link between New South Wales and South Australia and BassLink between Tasmania and Victoria. A major barrier to wider adoption of merchant transmission is the difficulty in identifying who benefits from the facility so that the beneficaries will pay the toll. Also, it is difficult for a merchant transmission line to compete when the alternative transmission lines are subsidized by other utility businesses.• Health concerns The current mainstream scientific view is that power lines are unlikely to pose an increased risk of cancer or other somatic diseases. For a detailed discussion of this topic, including references to a variety of scientific studies, see the Power Lines and Cancer FAQ. The issue is also discussed at some length in Robert L. Park's book Voodoo Science. It is argued by some that living near high voltage power lines presents a danger to animals and humans. Some have claimed that electromagnetic fields from power lines elevate the risk of certain types of cancer. Some studies support this theory, and others do not. Most studies of large populations fail to show a clear correlation between cancer and the proximity of power lines, but a 2005 Oxford University study did. One possible response to the dangers of overhead power lines is to bury them underground. When colocated with other utility infrastructure, this creates a common utility duct. In reality, protection from the dangers of electromagnetic fields is seldom the driving concern in burying power lines. See also | |||||||||||||
|
| ||||||||||||||
![]() |
|
| |