|- align = "center" | |width = "25"| | |width = "25"| | |- align = "center" | Signal ground | | Chassis ground | | Earth ground The term ground or earth usually means a common return path in electrical circuits. The terms Earth return and ground return are also common.
Meanings In electrical engineering, the term ground or earth has the following meanings: Uses A power ground serves to provide a return path for fault currents and therefore allow the fuse or breaker to disconnect the circuit. The power ground is also often bonded to the house's incoming pipework, and pipes and cables entering the bathroom are sometimes cross-bonded. This is done to try to reduce the voltage between objects that can be touched simultaneously. Filters also connect to the power ground, but this is mainly to stop the power ground carrying noise into the systems which the filters protect, rather than as a direct use of the power ground. See: NEC (Article 250). In Single Wire Earth Return (SWER) electrical distribution systems, costs are saved by using just a single high voltage conductor for the power grid, while routing the AC return current through the earth. This system is mostly used in rural areas where large earth currents will not otherwise cause hazards. Signal grounds serve as return paths for signals and power at low voltages (less than about 50 V) within equipment, and on the signal interconnections between equipment. Many electronic designs feature a single return that acts as a reference for all signals. Power and signal grounds often get connected together, usually through the metal case of the equipment. Lightning protection is a very specialised form of grounding used in an attempt to divert the huge currents from lightning strikes. Grounding is primarily used for safety to prevent electric shock or fires caused by a voltage potential between the earth and a conductor such as an appliance cabinet or chassis. Grounding is often used to conduct lightning strikes harmlessly to earth rather than starting fires and damaging equipment. It is also used to control electrical noise in computer, audio and video, and communications circuits. This illustrates that an electrical ground should have an appropriate current-carrying capability in order to serve as an adequate zero-voltage reference level. History Long-distance electromagnetic telegraph systems from 1820 onwards used two or more wires to carry the signal and return currents. It was then discovered, probably by the German scientist Carl August Steinheil in 1836-1837 *, that the ground could be used as the return path to complete the circuit, making the return wire unnecessary. However, there were problems with this system, exemplified by the transcontinental telegraph line constructed in 1861 by the Western Union Company between Saint Joseph, Missouri, and Sacramento, California. During dry weather, the ground connection often developed a high resistance, requiring water to be poured on the ground rod to enable the telegraph to work or phones to ring. Later, when telephony began to replace telegraphy, it was found that the currents in the earth induced by power systems, electrical railways, other telephone and telegraph circuits, and natural sources including lightning caused unacceptable interference to the audio signals, and the two-wire system was reintroduced. See also Source | ||||||||
|
| |||||||||
![]() |
|
| |