    Arterial blood gas measurement is a blood test that is performed to determine the concentration of oxygen, carbon dioxide and bicarbonate, as well as the pH, in the blood. Its main use is in pulmonology, as many lung diseases feature poor gas exchange, but it is also used in nephrology (kidney diseases) and electrolyte disturbances. As its name implies, the sample is taken from an artery, which is more uncomfortable and difficult than venipuncture.

        Arterial blood gas
            Obtaining and processing the sample
            Interpretation
            Reference ranges

    top

    Obtaining and processing the sample
    Arterial blood is taken from any easily accessible artery (typically either radial, brachial or femoral) or out of an arterial line. The syringe is prepacked and contains a small amount of heparin, to prevent coagulation or needs to be heparinised, by drawing up a small amount of heparin and squirting it out again.

    Once the sample is obtained, care should be taken to eliminate visible gas bubbles, as these bubbles can dissolve into the sample and cause inaccurate results. The sealed syringe is taken to a blood gas monitor. If the sample cannot be immediately analyzed it should be chilled in an ice bath to slow metabolic processes that may also cause inaccuracy. The machine aspirates this blood from the syringe and measures the pH and the partial pressures of oxygen and carbon dioxide and the bicarbonate concentration, as well as the oxygen saturation of hemoglobin. Some machines can also measure glucose, lactate, hemoglobin and limited electrolytes (sodium and potassium).

    The results are usually available within five minutes, and are now ready for interpretation.

    top

    Interpretation
    The pH or H+ indicates if a patient is acidotic (pH <7.35; H+ >45) or alkalotic (pH > 7.45; H+ < 35). The carbon dioxide partial pressure (PCO2) indicates a respiratory problem: for a constant metabolic rate, the PCO2 is determined entirely by ventilation. A high PCO2 (respiratory acidosis) indicates underventilation, a low PCO2 (respiratory alkalosis) hyper- or overventilation. The HCO3- ion or base excess indicates whether a metabolic problem is present (such as ketoacidosis). A low HCO3- or negative base excess indicates metabolic acidosis, a high HCO3- or high positive base excess, metabolic alkalosis.

    Contamination with room air will result in abnormally low carbon dioxide and (generally) high oxygen levels. Delays in analysis (without chilling) will result in inaccurately low oxygen and high carbon dioxide levels as a result of ongoing cellular respiration.

    top

    Reference ranges
    These are typical reference ranges, although various analysers and laboratories may employ different ranges.


    Lactate levels are often included on blood gas machines in neonatal wards; infants often have elevated lactic acid.
     